Ayuda
Ir al contenido

Dialnet


Influência da irradiação com lasers de alta potência na microinfiltração bacteriana e fúngica em dentes humanos retrobturados com MTA

  • Autores: Carmo Antonio Aun
  • Directores de la Tesis: Giulio Gavini (dir. tes.)
  • Lectura: En la Universidade de São Paulo (USP) ( Brasil ) en 2008
  • Idioma: portugués
  • Número de páginas: 106
  • Enlaces
    • Tesis en acceso abierto en: Dialnet
  • Resumen
    • español

      Este estudio experimental in vitro evaluó ia microflitraclón de E. faecalis y C. albicans en cuyas raíces ressectaed apical y superticies retrocavities habían sufrido irradiación de Nd: YAG, Diodo 810 nm y de Er, Cr: YSGG los láser, y más tarde con relrofiled MTA. Setenta raíces se había preparado, obturated, había sufrido apicectomia y se retroprepared con diamante convencional y ulira-sónico consejos en la potencia media. La divisiôn de las muestras flue de conformidad con ei láser utilizado y ei tipo de microorganismo. Los grupos Gi y G5 no se había irradiado, G2 y G6 irradiados con Nd: YAG, G3 y G-7 con Diodo y G4 y G8 con Er, Cr: YSGG (n = 8). Positivos (n = 3) y negativos (n = 3) los controles se han utilizado. Todos los procedimientos de ejecución hasta este punto se había llevado dentro de un dispositivo de simuiación de Ias dificultades de acceso. Después de la impermeabilización, fljación de las raíces en los tubos preparados y la esterilización, la retrofiulings se realizaron utilizando MTA blanco. El superior câmaras fueron inoculadas con los microorganismos y Ias câmaras inferiores se completa con ei caldo de cultivo estéril en contacto con la punta de ia raiz. El Gi, G2, G3 y G4 grupos había sido inoculado con E. faecalis y ei resto de los grupos con C. albicans. Los caldos contaminados de ias cámaras superiores se intercambiaron cada 3 dias y por 60 dias la veritlcación de ia turbidez en la inferior las cámaras se evaiuó diariamente. Ai final, los resultados indicaron que: ei control positivo de 100% microfiitración, ei conirol negativo y ninguno de los grupos experimentales había presentado microleakege patrones que van desde 50% (G1) y ei 100% (G2), con un total de 68,75 % de todos los especímenes que presenta la microfiltración. Aplicando la prueba exacta de Fischer y la prueba de Kruskal-Waliis (p> 0,05), sin diferencia estadística significativa entre los grupos fueron observados en cuaiquier interacción. Se puede concluir que ei tratamiento de la retrocavities y ressected superlicie apical, con ei láser utilizado en este estudio, no modificó ia tasa de E. faecalis y C. albicans en la microfiltración dei MTA retrofihlings. También ei tipo de microorganismo utilizado no parece modificar ei importe de la microfiltración en los especímenes.

    • English

      This in vitro experimental study evaluated lhe microleakage of E. faecalis and C. albicans in roots whose ressected apical surfaces and retrocavities had suffered irradiation from Nd:YAG, Diode 810 nm and Er,Cr:YSGG lasers, and later retrofiled with MTA. Seventy roots had been prepared, obturated, had suffered apicoectomy and were retroprepared with diamond and conventional ultrasonic tips in the average power. The division of specimens was in accordance with the used laser and the type of microorganism. The groups G1 and G5 had not been irradiated, G2 and G6 irradiated with Nd:YAG, G3 and G7 with Diode and G4 and G8 with Er, Cr:YSGG (n = 8). Positive (n = 3) and negative (n = 3) controls had been used. All procedures executed until this point had been carried inside an access difficulties simulation device. After the waterproofing, attachment of the roots in prepared tubes and sterilization, the retrofillings were made using white MTA. The superior chambers were inoculated with the microorganisms and inferior chambers were completed with sterile culture broth in contact with the root tip. The G1, G2, G3 and G4 groups had been inoculated with E. faeca!is and the rest of the groups with C. albicans. The contaminated broths of the upper chambers were exchanged each 3 days and for 60 days the verification of the turbidity in the inferior chambers was evaluated daily. At the end, the results had indicated that: the positive control had 100% microieakage, the negative control none and the experimental groups had presented microieakege patterns that range from 50% (G1) to 100% (G2), with a total of 68.75% of all specimens presenting microleakage. Applying the Exact Fischer test and Kruskai-Wallis test (p > 0,05), no significant statistical difference between the groups were observed in any interaction. lt can be concluded that the treatment of the retrocavities and ressected apical surface, with the lasers used in this study, did not modify the rate of E. faecalis and C. a!bicans microleakage in MTA retrofillings. Also the type of used microorganism did not seem to modify the amount of microleakage in the specimens.

    • português

      Este estudo experimental avaliou, in vitro, a microinfiltração de E. faecalis e C. albicans em raízes cujas superfícies apicais ressectadas e retropreparadas para obturação retrógrada sofreram irradiação dos lasers Nd:YAG, Diodo 810 nm e Er,Cr:YSGG, e posteriormente relrobturadas com MTA. Setenta raízes foram instrumenladas, obturadas endodonticamente, apicectomizadas e receberam relropreparos com pontas ultra-sônicas diam antadas e lisas na potência média. A divisão dos espécimes se deu de acordo com o iaser utilizado e o tipo de microorganismo. Os grupos Gi e G5 não foram irradiados, G2 e G6 irradiados com Nd:YAG, G3 e G7 com Diodo e G4 e G8 com Er,Cr:YSGG (n = 8). Foram utilizados controles positivo (n 3) e negativo (n = 3). Todos os procedimentos operatórios foram realizados com um dispositivo de simulação de dificuldades operatôrias. Após a impermeabilização, colagem das raízes em tubos preparados, esterilização e refrobturação com MTA branco, o sistema de câmaras superior, contendo o inóculo de microorganismos, e inferior, contendo meio esterilizado foi montado em contato com o ápice. Os grupos G1 a G4 foram inoculados com E. faecalls, e os grupos G5 a G8 com C. albicans. A troca de meio na câmara superior se deu a cada 3 dias e a verificação da turvação do meio inferior era diária, por um período de 60 dias. Ao final, os resultados indicaram que: o controle positivo apresentou 100% de microinfihtração, o controle negativo não microinfiltrou e os grupos experimentais apresentaram padrões de microinfiltração que variaram entre 50% (Gi) e 100% (G2) de microinfiltraçâo, onde 68,75% do total de espécimes microinfiltraram. Não houve diferença estatística significativa entre os grupos aplicando-se os testes Exato de Fischer e Kruskal-Wallis (p > 0,05) em nenhuma interação. Pode-se concluir que o tratamento das retrocavidades e superfície apical ressectada, com os lasers utilizados neste estudo, não alterou o padrão de microinfiltração das retroblurações com MTA frente a E. faeca!ís e C. albicans. O tipo de microorganismo utilizado também não alterou a quantidade de espécimes microintiltrados.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno