Ayuda
Ir al contenido

Dialnet


Thermo-optical and thermo-elastic effects onboard the lisa pathfinder mission

  • Autores: Francisco Rivas García
  • Directores de la Tesis: Carlos Fernández Sopuerta (dir. tes.), Miquel Nofrarias Serra (dir. tes.)
  • Lectura: En la Universitat Autònoma de Barcelona ( España ) en 2019
  • Idioma: español
  • Tribunal Calificador de la Tesis: Rita Dolesi (presid.), Jordi Mompart (secret.), José María Gómez Cama (voc.)
  • Programa de doctorado: Programa de Doctorado en Física por la Universidad Autónoma de Barcelona
  • Materias:
  • Enlaces
    • Tesis en acceso abierto en: TESEO
  • Resumen
    • The LISA Pathfinder mission has paved the way to the Gravitational-Wave space astronomy. Not only it tested the technology needed by a space observatory LISA-like, but also studied and analysed the non-gravitational forces that appear between two free-falling test masses. Indeed, after about a year and a half of the mission (including commissioning, science operation, and extension phases), the satellite measured a residual acceleration noise between the masses of 1.74 fm s^{-2}/ \sqrt{Hz} above 2 mHz. It is an improvement of approximately a factor 15 with respect to the LISA Pathfinder requirement established before the mission, and a factor 5 with respect to the LISA requirement at that time. This achievement has been possible thanks to the fact that the spacecraft had different subsystems which, besides acting on 15 degrees of freedom of the spacecraft, allowed to perform experiments to estimate and subtract the different disturbances.

      Thermal fluctuations were one of the sources of perturbation that modified the relative acceleration between both test masses. Depending on whether they induce real forces on the masses or only changes in the optical path length, we distinguish two kinds of thermal disturbances, namely: those that are around the test masses and which produce real forces on them, and those that appear in locations such as the optical windows or the struts (thermo-optical and thermo-elastic contributions), where these thermal fluctuations can produce distortions that in turn change the optical path length of the laser. Aiming to monitor and analyse the temperature onboard the satellite, it was equipped with 24 thermal sensors and 14 heaters distributed around the more critical parts of the instrument. With the thermal sensors, we measured the temperature in those locations, and with the heaters, we stimulated thermally those components where the two kinds of thermal disturbances commented before could act.

      In this thesis, in addition to showing the main results obtained during LISA Pathfinder, I focus on the temperature. I will show how the temperature evolved thorough the mission in its different phases and the thermal stability we achieved. Furthermore, I present the different in-flight experiments carried out to analyse and estimate the thermo-optical and thermo-elastic contributions. Finally, we discuss the implications of these analysis to the future Gravitational-Wave observatory, LISA.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno