Ayuda
Ir al contenido

Dialnet


A new structure for line-start non-slotted axial-flux permanent magnet motor, proposing a novel 3D FEA-based demagnetization reduction approach

    1. [1] Kosar University of Bojnord

      Kosar University of Bojnord

      Irán

    2. [2] Electrical Engineering Research and Development Branch, Samen Pharmaceutical Company, Mashhad, Iran
  • Localización: Compel: International journal for computation and mathematics in electrical and electronic engineering, ISSN 0332-1649, Vol. 42, Nº 6, 2023, págs. 1225-1247
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Purpose This paper aims to propose a novel simple and efficient structure for line-start axial-flux permanent magnet (LSAFPM) synchronous motor, especially regarding the permanent magnets (PMs) demagnetization reduction.

      Design/methodology/approach At first, a primitive raw scheme of the new structure for the LSAFPM motor is introduced. Considering this raw scheme, the levels of irreversible demagnetization in various regions throughout the entire volume of each PM are evaluated using 3 dimensional (3D) finite elements analysis (3D FEA) in full loading condition during startup until reaching steady state. Based on the results of these analyses, the primitive structural scheme is then modified through segmenting (cutting into four pieces) each PM from where the worst irreversible demagnetization levels occurred.

      Findings As will be demonstrated by the results of 3D FEA, the proposed modified structure is not only capable of successful startup and synchronization of the motor but also it considerably reduces the PM demagnetization level. Thus, the performance of the motor is significantly improved.

      Originality/value The demagnetization of PMs is an important effect in PM synchronous motors, which can greatly affect motor performance. Therefore, it is necessary to be considered in the motor design processes. This effect becomes much more significant in the line-start PM motors because the usual high-magnitude startup induction current produces a strong armature-reaction magnetic field, which may cause the PMs to be irreversibly demagnetized. The approach proposed in this paper provides a structural solution to mitigate the PM demagnetization effect and thereby improve the performance of an LSAFPM motor through modifying the structure of the LSAFPM motor according to an FEA-based PM demagnetization analysis. As a considerable contribution, in this analysis, the variation of demagnetization level between different areas inside each PM is computed and is considered as a basis for proposing an appropriate structural modification to mitigate the PM demagnetization effect as much as possible.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno