Ayuda
Ir al contenido

Dialnet


Resumen de Cánula nasal de alto flujo en lactantes: experiencia en una unidad de paciente crítico

Adriana Wegner Araya, Pamela Céspedes F, María Loreto Godoy M, Pedro Erices B, Luis Urrutia C, Carina Venthur U, Marcela Labbé C, Hugo Riquelme Muñoz, Cecilia Sanchez J, Waldo Vera V, David Wood V, Juan Carlos Contreras C, Efren Urrutia S

  • español

    Introducción: La cánula nasal de alto flujo (CNAF) es un método de soporte respiratorio cada vez más utilizado en pediatría por sus resultados y seguridad. Objetivo: Determinar la efectividad de la CNAF, evaluar factores asociados a fracaso y complicaciones relacionadas con su uso en lactantes. Pacientes y método: Se analizaron los datos demográficos, clínicos, gasométricos, radiológicos y complicaciones de los pacientes conectados a CNAF en una unidad crítica entre junio de 2012 y septiembre de 2014. Se compararon los pacientes que fracasaron con los respondedores a CNAF, considerándose fracaso la necesidad de un mayor soporte respiratorio durante las primeras 48 h de conexión. Se utilizó test de Kolmogorov Smirnov, U de Mann-Whitney, Chi cuadrado, test exacto de Fisher, correlaciones y Modelo de regresión logística binaria para p ≤ 0,05. Resultados: Un total de 109 pacientes. Mediana de edad y peso: 1 mes (0,2-20 meses) y 3,7 kg (2-10 kg); percentil 95: 3,7 meses y 5,7 kg respectivamente. El diagnóstico y patrón radiológico más frecuente fue bronquiolitis (53,2%) e infiltrado intersticial (56%). Un 70,6% respondió. Hubo diferencia significativa entre fracaso y respuesta en el diagnóstico (p = 0,013), radiografía (p = 0,018), contexto de conexión (p < 0,0001), pCO2 (mediana 40,7 mm Hg [15,4-67 mm Hg] versus 47,3 mm Hg [28,6-71,3 mm Hg], p = 0,004) y horas de CNAF (mediana 60,75 h [5-621,5 h] versus 10,5 h [1-29 h], p < 0,0001). El OR de PCO2 ≥ 55 mm Hg para fracaso fue 2,97 (IC 95%: 1,08-8,17; p = 0,035). Ningún paciente falleció ni registró complicaciones. Conclusión: El porcentaje de éxito observado fue similar a lo publicado. En esta muestra el fracaso de CNAF solo se asoció a una pCO2 inicial ≥ 55 mm Hg. Su uso se consideró seguro al no reportarse complicaciones relacionadas a su utilización. Se requiere de un estudio multicéntrico, aleatorizado y controlado para contrastar estos resultados.

  • English

    Introduction: The high flow nasal cannula (HFNC) is a method of respiratory support that is increasingly being used in paediatrics due to its results and safety. Objective: To determine the efficacy of HFNC, as well as to evaluate the factors related to its failure and complications associated with its use in infants. Patients and method: An analysis was performed on the demographic, clinical, blood gas, and radiological data, as well as the complications of patients connected to a HFNC in a critical care unit between June 2012 and September 2014. A comparison was made between the patients who failed and those who responded to HFNC. A failure was considered as the need for further respiratory support during the first 48 hours of connection. The Kolmogorov Smirnov, Mann-Whitney U, chi squared and the Exact Fisher test were used, as well as correlations and a binary logistic regression model for P ≤ .05. Results: The study included 109 patients, with a median age and weight: 1 month (0.2-20 months) and 3.7 kg (2-10 kg); 95 percentile: 3.7 months and 5.7 kg, respectively. The most frequent diagnosis and radiological pattern was bronchiolitis (53.2%) and interstitial infiltration (56%). Around 70.6% responded. There was a significant difference between failure and response in the diagnosis (P = .013), radiography (P = 018), connection context (P < .0001), pCO2 (median 40.7 mmHg [15.4-67 mmHg] versus 47.3 mmHg [28.6-71.3 mmHg], P = .004) and hours on HFNC (median 60.75 hrs [5-621.5 hrs] versus 10.5 hrs [1-29 hrs], P < .0001). The OR of the PCO2 ≥ 55 mmHg for failure was 2.97 (95% CI; 1.08-8.17; P = .035). No patient died and no complications were recorded. Conclusion: The percentage success observed was similar to that published. In this sample, the failure of HFNC was only associated with an initial pCO2 ≥ 55 mmHg. On there being no complications reported as regards it use, it is considered safe, although a randomised, controlled, multicentre study is required to compare and contrast these results.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus