Ayuda
Ir al contenido

Dialnet


Biomechanics of anterior endocrowns with different designs and depths: study of finite elements

    1. [1] Universidad Nacional de Trujillo

      Universidad Nacional de Trujillo

      Provincia de Trujillo, Perú

  • Localización: Journal of Clinical and Experimental Dentistry, ISSN-e 1989-5488, Vol. 15, Nº. 12 (December), 2023, págs. 1016-1021
  • Idioma: inglés
  • Enlaces
  • Resumen
    • To date, there is no clear consensus in the literature on which endocrown design and depth is the most effective treatment option for restoring endodontically treated maxillary central incisors. Aim: To determine the stress distribution of the anterior endocrowns by means of finite element analysis.

      Nine 3D finite element models (groups A – I) were made, each one representing a restoration system of endodontically treated upper central incisors. The models were endocrowns with and without ferrules at 0, 1, 3, and 5 mm depth and a post-core stump control group. A static load of 100N of force was applied to the palatal face at 45º from the long axis of the tooth. The Von Mise values and the maximum stress in the crown, dentin and resin cementum were evaluated separately.

      The maximum stress distribution was C < B < A < D < H < F < E < G < I and the Von Mises stresses were in the upper 1/3 of the retainer of endocrowns A, B, C and D. ; in the vestibular neck in endocrowns E and F; in the final 1/3 of the retainer in the endocrown G; in the middle 1/3 of the retainer in the H endocrown; and at the level of the vestibular neck of the crown in model I.

      The smallest distribution of maximum and Von Mises stresses was observed in model C.