Evaluation of the impact of parameters on the gamma index for breast cancer treatments

    1. [1] Universidad Nacional de Ingeniería

      Universidad Nacional de Ingeniería

      Perú

    2. [2] Universidad Nacional Mayor de San Marcos

      Universidad Nacional Mayor de San Marcos

      Perú

    3. [3] Instituto Nacional de Enfermedades Neoplásicas, Lima, Perú
  • Localización: Revista Mexicana de Física, ISSN-e 0035-001X, Vol. 67, Nº. 6, 2021, págs. 949-954
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Volumetric modulated arc radiotherapy treatments (VMAT) can achieve highly conformed dose distributions however, due to the complexity of the technique, there may have differences between the planned and administered dose distributions, generated by the precision in the dose calculation of the treatment planning system (TPS) or by the errors associated with it. One way to quantify the difference between both dose distributions is by using the gamma index; however, there is no accord regarding the parameters that should be used in its analysis. On the other hand, this gamma index may depend on the pathology and the area to be treated. For this reason, the present work aims to evaluate different parameters of the analysis of the gamma index for breast cancer treatments; these are local and global normalization, the analysis criteria (1%/1 mm, 2%/2 mm, 3%/2 mm, 2%/3 mm, 3%/3 mm and 5%/3 mm), and the low dose threshold (LDT) of 5% and 10%. For this, 30 treatment plans performed with VMAT technique in a 6 MV Infinity linear accelerator (Elekta, Stockholm, Sweden) were analyzed, calculated with the TPS Monaco V.5.11.03 (Elekta, Stockholm, Sweden) and measured with the Octavius 4D system (PTW, Freiburg, Germany). The results of the analysis of the global gamma index were of a gamma passing rate (%GP) greater tan 95% for analysis criteria of 3%/3 mm and 5%/3 mm; however, for these same parameters in the local gamma index analysis, the results are 85.8% and 91.1% respectively. In addition, from the LDT evaluation, it is observed that there is a mean increase of % GP for the local gamma index analysis and a mean decrease of % GP for the global gamma index analysis, for the LDT from 5% to 10%. On the other hand, the standard deviation is lower in the global gamma index; analysis than in the local one, and it decreases when the analysis criteria are less strict. It is concluded that there is not a great difference in choosing the LDT of 5% or 10%. When the gamma analysis criteria are less strict, the %GP increases both for the analysis of the local and global gamma index, taking this into account, each parameter should be used carefully according to the treatment plan to be analyzed, taking into account the advantages and disadvantages of each parameter.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno