Ayuda
Ir al contenido

Dialnet


cei-uci:: instrumento para evaluar el cuidado de enfermería individualizado de adultos en la uci

    1. [1] Universidad Nacional de Colombia

      Universidad Nacional de Colombia

      Colombia

    2. [2] Magíster en Educación. Bogotá, Colombia
  • Localización: Avances en Enfermería, ISSN 0121-4500, ISSN-e 2346-0261, Vol. 33, Nº. 1, 2015, págs. 104-113
  • Idioma: español
  • Títulos paralelos:
    • cei-icu:: an instrument for evaluating individualized nursing care adult in icu
    • cei-uti:: instrumento para avaliar os cuidados de enfermagem individualizados no adulto na uti
  • Enlaces
  • Resumen
    • español

      El propósito de este estudio fue diseñar el instrumento Cuidado de Enfermería Individualizado en Unidad de Cuidado Intensivo (cei-uci) para identificar las in-tervenciones de cuidado de enfermería individualizado en pacientes con venti-lación mecánica invasiva en la uci. Metodología: Estudio psicométrico, exploratorio-observacional, con n = 156 enfermeras que laboraban en la ucicon pacientes adultos en ventilación mecánica. Se diseñaron un total de 85 ítems para iniciar las pruebas. Para la validez facial se utilizó la V. Aiken por encima de 0,70. Para la validez de con-tenido se realizó el cálculo de Lawshe Modificado igual o mayor a de 0,58. La validez de constructo se obtuvo por medio del análisis factorial con ocho dominios nanda. La confiabilidad se re-portó con test-retest para los días 1, 2 y 3 de estadía de los pacientes en uci. Resultados: El cei-uci presentó una validez facial con rangos entre 0,75-0,82, con un cvi con rangos entre 0,58-0,90. La validez de constructo se confirmó con una varianza total explicada del 73% para cuatro factores. La confiabilidad por el test-retest entre los tres primeros días de aplicado el instrumento se presentó con un rango de 0,662 a 1,00. Conclusiones: El instrumento cei-uci posee 53 ítems y seis dimensiones con validez facial, aparente y consistencia interna. La validez de constructo derivada del análisis facto-rial de cuatro factores se denominaron Dimensiones, a saber: F1, Protección y seguridad (17 ítems); F2, Interacción fisiológica y social (3 ítems); F3, Roles y conexiones sociales (13 ítems); y F4, Autopercepción y nutrición (11 ítems). Además, hubo dos dimensiones permanentes y centinelas: Perceptual-Cognitivo y el de Confort.

    • English

      The proposal of this study was to design an instrument of individualized nursing care in intensive care unit (cei-uci) so as to characterize the interventions of care, in adults with artificial respiration at risk of delirium in uci. Methodology: Observational exploration with 156 nurses working in uci with adult patients under artificial respiration. A total of 85 items are identified so as to initiate the test. For facial validation, it requires an Aiken indexabove 0,70. For the content validity, a modified Lawshe equal or superior to 0,58 was calculated. For the construct validation, a factorial analysis with eight nanda domains was used. Results: The instrument cei-uci had facial validity between 0,75 and 0,82 and cvi between 0,58 and 0,90. The construct validity was confirmed by a total variance of the 73% for four factors. The reliability by means of test-re-test among the first three days in ucicame with a range from 0,662 to 1,00. Conclusions: The psychometric instrument cei-uci has obvious facial validity, content validity and constructs validity. This is supported by the factorial analysis showing multi-dimensionalility with four factors: F1, Protection and security (17 items); F2, Physiological and social interactions (3 items); F3, Roles and social connections(13 items) and F4, Self-perceptions and nutrition (11 items). Furthermore, there were united permanent domains: the Perceptual-Cognitive and the Comfortwith items derived from care rather than the factorial analysis. The prod-uct was the instrument cei-uci with 53 items for adults under artificial respiration and monitored for delirium using acceptable psychometric tests.

    • português

      O objetivo deste estudo foi construir o instrumento Cuidado de Enfermagem Individualizado em Unidade de Terapia Intensiva Adulto (cei-uci) para identificar intervenções de cuidados de enfermagem individualizados em pacientes adultos com ventilação mecânica invasiva na uti. Metodologia: Estudo psicométrico, exploratório-observacional, com n= 156 enfermeiras que trabalham em uti com pacientes em ventilação mecânica: foram desenvolvidos um total de 85 itens para começar os testes. Para a validade facial foi utilizada a V. de Aiken acima de 0,70. Para a validade de conteúdo foi utilizado o cálculo estatístico de Lawshe Modificado acima de 0,58. A validade de construto foi realizada por meio de análise fatorial com oito dos dez domínios nanda. A confiabilidade se deu por meio do teste-reteste para os dias 1, 2 e 3 de permanência dos pacientes na uti. Resultados: A cei-uti apresentou validade facial que variou entre 0,75-0,82, com cvi entre 0,58-0,90. Quanto à validade de construto confirmou variância total explicada de 73% para os quatro fatores. A confiabilidade por meio do teste-reteste entre os três primeiros dias de aplicação do instrumento variou de 0,662 a 1,00. Conclusões: O instrumento cei-ucitem 53 itens, seis dimensões com validade de face, e da consistência interna aparente. A validade de construto derivado da análise fatorial de quatro fatores que são chamados Dimensões: F1, Proteção e segurança (17 itens); F2, Interação fisiológica e social (3 itens); F3, Roles e conexões sociais (13 itens) e F4, Auto-percepção e nutrição (11 itens). Há também duas dimensões permanentes e sentinelas: Percepção e de Cognição e Conforto.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno