Effect of magnetic slot wedge on the performance of bulb tubular turbine generator

    1. [1] Zhengzhou University of Light Industry

      Zhengzhou University of Light Industry

      China

    2. [2] University of Light Industry, Zhengzhou, China
    3. [3] Wolong Electric Nanyang Explosion Protection Group Co., Ltd., Nanyang, China
  • Localización: Compel: International journal for computation and mathematics in electrical and electronic engineering, ISSN 0332-1649, Vol. 39, Nº 4, 2020, págs. 160-171
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Owing to the salient pole structure and stator slots of hydro-generator, the air gap magnetic field in the generator is unevenly distributed. High-frequency harmonic components contained in the inhomogeneous air gap magnetic field will have a negative impact on the generator performance. The purpose of this paper, therefore, is to improve the distribution of air gap magnetic field by using appropriate magnetic slot wedge, thereby improving the generator performance.