Ayuda
Ir al contenido

Dialnet


Aplicativo para dispositivos móveis é alternativa válida para medida de altura em saltos verticais em lutadores

    1. [1] Universidad Federal de Pará

      Universidad Federal de Pará

      Brasil

  • Localización: Revista andaluza de medicina del deporte, ISSN 1888-7546, Vol. 12, Nº. 2, 2019, págs. 83-87
  • Idioma: portugués
  • Títulos paralelos:
    • Application for mobile devices is a valid alternative for vertical jump height measurement in fighters
    • Aplicación para dispositivos móviles como alternativa válida para medición de la altura en saltos verticales en luchadores
  • Enlaces
  • Resumen
    • español

      Objetivo:Investigar la confiabilidad y reproducibilidad de la aplicación Jumpo® para la medida de saltos verticales en luchadores.Método: Participaron 16 atletas de ambos os sexos con edad media de 19 ± 5 años, estatura de 1.7 ± 0.1 m, masa corporal de 65 ± 15 kg. La presenteinvestigación contabilizó dos encuentros en los que se realizaron pruebas y re-test de ambos instrumentos de evaluación para los siguientes saltosverticales: Countermovement Jump, Squat Jump y Drop Jump, medidos simultáneamente con la Superfície de Contacto y el Jumpo®. Se analizaron eltiempo de contacto con el suelo y la altura máxima de salto. Para el análisis estadístico se aplicó coeficiente de correlación intraclase destinado a lasevaluaciones intra e inter-evaluadores. Los comparativos entre Jumpo® y la superfície de contacto se utilizaron nuevamente el coeficiente de correlaciónintraclase y el análisis gráfico de Bland-Altman.Resultados: Concordancias "casi perfectas" para altura máxima en todos los saltos, tanto intra-evaluadores (CCI = 0.911-0.959), como inter-evaluadores(CCI = 0.939-0.951) e inter-instrumentos (CCI = 0.939-0.972) encontrado. Sin embargo, el tiempo de contacto con el suelo no presentó concordanciasignificante inter-instrumentos (p <0.360). Sin embargo, se encontraron valores inter-evaluadores estadísticamente significativos (p <0.001).Conclusión: El Jumpo® parece ser una herramienta válida y reproducible para medida de altura máxima de saltos verticales, pero no para el tiempo decontacto. Se sugiere, por lo tanto, que entrenadores y técnicos puedan ser alentados a utilizar esta herramienta para evaluación y monitoreo deldesempeño de saltos en luchadores.

    • English

      Objective: To investigate the reliability and reproducibility of the Jumpo® application for vertical jumping measurement.Method: 16 athletes of both sexes with a mean age of 19 ± 5 years, height of 1.7 ± 0.1 m, body mass of 65 ± 15 kg were included. The present investigationcounted two meetings, in which test-retest of both assessment instruments for the following vertical jumps: Countermovement Jump, Squat Jump andDrop Jump, measured simultaneously with the Contact Mat and Jumpo®. Contact time with soil the ground and maximum jump height were analyzed.For statistical analysis, intraclass correlation coefficient was applied for intra- and inter-rater assessments. The comparisons between Jumpo® andcontact mat performed by intraclass correlation coefficient and the Bland-Altman graphic analysis.Results: Almost perfect agreement for maximum height in all jumps, both intra-rater (ICC = 0.911-0.959), and inter-rater (ICC = 0.939-0.951) and inter-instrument (ICC = 0.939-0.972) were found. However, the contact time presented no significance (p <0.360) in relation to inter-instrumentmeasurements. However, statistically significant inter-rater values were found (p <0.001).Conclusion: Jumpo® seems to be a valid and reproducible tool for measuring maximum vertical jumps height, but not for contact time. It is suggested,therefore, that coaches and trainers can be encouraged to use this tool for evaluation and monitoring of jumping performance in fighters.

    • português

      Objetivo: Investigar a confiabilidade e reprodutibilidade do aplicativo Jumpo® para medida de saltos verticais de lutadores. Método: Participaram 16 atletas de ambos os sexos com idade média de 19 ± 5 anos, estatura de 1.7 ± 0.1 m, massa corporal de 65 ± 15 kg. A presenteinvestigação contabilizou dois encontros, nos quais foram realizados teste-reteste de ambos os instrumentos de avaliações para os seguintes saltosverticais: Countermovement Jump, Squat Jump e Drop Jump, medidos simultaneamente com o Tapete de Contato e o Jumpo®. Foram analisados o tempode contato com o solo e a altura máxima de salto. Para análise estatística foi aplicado coeficiente de correlação intraclasse destinado às avaliações intra einter-avaliadores. Já os comparativos entre Jumpo® e tapete de contato foram utilizados novamente o coeficiente de correlação intraclasse e a análisegráfica de Bland-Altman.Resultados: Concordâncias “quase perfeitas” para altura máxima em todos os saltos, tanto intra-avaliadores (CCI= 0.911-0.959), como inter-avaliadores(CCI= 0.939-0.951) e inter-instrumentos (CCI= 0.939-0.972) foram encontradas. Porém, o tempo de contato com o solo não apresentou concordânciasignificante interinstrumentos (p<0.360). Entretanto, foram encontrados valores inter-avaliadores estatisticamente significativos (p<0.001).Conclusão: O Jumpo® parece ser uma ferramenta válida e reprodutível para medida de altura máxima de saltos verticais, mas não para o tempo decontato com o solo. Sugere-se, portanto, que treinadores e técnicos podem ser encorajados a utilizar esta ferramenta para avaliação e monitoramento dodesempenho de saltos em lutadores.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno