Ayuda
Ir al contenido

Dialnet


Resumen de In vitro effect of temperature on dentin bond strength of universal adhesive systems

Serdar Akarsu, Sultan Aktug Karademir

  • español

    El objetivo de este estudio fue evaluar la resistencia al cizallamiento (SBS) de dos adhesivos universales (Universal Single Bond y All Bond Universal) y un sistema de adhesivo de autograbado de dos pasos (Clearfil SE Bond) a la dentina en diferentes temperaturas. Materiales y métodos: Ciento veinte muestras de dentina se dividieron aleatoriamente en 12 grupos, de acuerdo con los sistemas adhesivos (Universal Single Bond y All Bond Universal, Clearfil SE Bond) y la temperatura (4ºC, 20ºC, 36ºC, 55ºC) utilizada. Se prepararon muestras de dentina (n: 10), se aplicaron los sistemas adhesivos y se polimerizaron los cilindros compuestos. El análisis estadístico de los datos de SBS se realizó utilizando el análisis de varianza de dos vías (ANOVA) y la prueba post-hoc de Tukey's. Resultados: El Clearfil SE Bond mostró tener un SBS más alto que los adhesivos universales en todas las temperaturas evaluadas; sin embargo, no hubo una diferencia estadísticamente significativa (P> 0.05). En todos los grupos, los valores más bajos de SBS se observaron en las muestras a 4°C, mientras que los valores de SBS más altos fueron obtenidos en las muestras a 55°C (P <0.05). Conclusiones: Los resultados sugieren que la efectividad de un adhesivo puede aumentar si se precalienta a 36°C o superior, antes de usarlo  inmediatamente después de sacarlo del refrigerador o a temperatura ambiente.

     

  • English

    The aim of this study was to evaluate the shear bond strength (SBS) of two universal adhesives (Universal Single Bond and All Bond Universal) and a two-step self-etch adhesive system (Clearfil SE Bond) to dentine at various temperatures. Materials and Methods: One hundred and twenty dentin specimens were divided randomly to 12 groups, according to adhesive systems (Universal Single Bond and All Bond Universal, Clearfil SE Bond)  and temperature  ( 4ºC, 20 ºC, 36ºC, 55ºC) used. Dentin specimens were prepared (n :10, adhesives were applied, and composite cylinders were polymerized. Statistical analysis of the SBS data was performed using Two-way analysis of variance (ANOVA) and Tukey’s Honestly Significant Differences post-hoc test. Results: The Clearfil SE Bond was shown to have higher SBS than the universal adhesives at all temperatures; however, there was no statistically significant difference (P>0.05). In both groups, the lowest SBS values were observed in the samples at 4°C while the highest SBS values were observed in the samples at 55°C. In this case, there was a statistically significant difference (P<0.05). Conclusions: The results suggest that the effectiveness of an adhesive may increase if it is preheated at 36°C or above before use instead of being used immediately after removal from the refrigerator or at room temperature.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus