Ayuda
Ir al contenido

Dialnet


Optimal energy saving of doubly fed induction motor based on scalar rotor voltage control and water cycle algorithm

    1. [1] Zagazig University

      Zagazig University

      Egipto

    2. [2] Menoufia University

      Menoufia University

      Egipto

  • Localización: Compel: International journal for computation and mathematics in electrical and electronic engineering, ISSN 0332-1649, Vol. 38, Nº 2, 2019, págs. 793-814
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Purpose – This paper aims to present an optimal variable speed drive of a doubly fed induction motor (DFIM) with minimum losses and reduced inverter capacity. The operation with minimum losses ensures that the DFIM develops the required load torque at desired speed with maximum energy saving. Moreover, the control of rotor voltage ensures the reduced inverter capacity. The water cycle algorithm (WCA) as one of meta-heuristic optimization techniques is used to estimate the optimal rotor voltages to drive the DFIM with minimum losses. The results of WCA are confirmed with other well-known and reliable optimization method such as particle swarm optimization along with classical method.

      Design/methodology/approach – The DFIM is an efficient alternative solution of synchronous motor (SM) because of its speed is synchronized with both stator and rotor frequencies regardless the load torque. As a result, the speed of variable speed drive associated with DFIM can be controlled through a rotor inverter with reduced capacity rather than SM. The output voltage of rotor inverter is controlled to develop the demanded output power with minimum motor losses.

      Findings – A complete DFIM drive model is developed under MATLAB/SIMULINK environment using d-q dynamic model to verify the strength and significance of the proposed controller. An experimental setup using a 300 W three-phase wound rotor induction motor is established to validate the mathematical models and theoretical results. The motor performances with proposed rotor voltage control (minimum losses) are compared with conventional method of constant voltage to frequency ratio (V/f constant). It is found that the proposed WCA based on controller achieves significant reductions in motor losses, input power and rotor inverter power.

      Originality/value – The paper presents an efficient method to maximize the energy saving of DFIM with a reduced inverter capacity using WCA.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno