Ayuda
Ir al contenido

Dialnet


Overcoming overshoot performance limitations of linear systems with reset control

  • Autores: Guanglei Zhao, Dragan Nešić, Ying Tang, Changchun Hua
  • Localización: Automatica: A journal of IFAC the International Federation of Automatic Control, ISSN 0005-1098, Nº. 101, 2019, págs. 27-35
  • Idioma: inglés
  • Texto completo no disponible (Saber más ...)
  • Resumen
    • It is well-known that for a class of minimum-phase relative degree one linear-time-invariant (LTI) systems, with a unit feedback control structure, overshoot necessarily happens if the plant transfer function has poles at origin or unstable poles. This work aims to overcome this overshoot performance limitation (OPL) by using a novel reset controller, which has a generalized first order reset element (GFORE) structure. By tuning parameters of this reset controller carefully, the non-overshoot performance can be ensured. Furthermore, the implementation of the proposed reset controller with a high-pass filter is provided. Parameter tuning guidelines are also provided and, finally, the proposed design is verified with a simulation example.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno