Analysis method of negative ion by electrostatic atomization

  • Autores: Yu Okaue, Gaku Yoshikawa, Fumikazu Miyasaka, Katsuhiro Hirata
  • Localización: Compel: International journal for computation and mathematics in electrical and electronic engineering, ISSN 0332-1649, Vol. 29, Nº 5 (Special Issue: ICEM 2008 Papers), 2010, págs. 1285-1293
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Purpose – The purpose of this paper is to propose an analysis method of negative ion by electrostatic atomization. Because the electrostatic atomization includes large deformation of a drop of water, it is difficult to analyze with conventional fluid analysis methods such as the finite differences method, the finite element method (FEM) and so on.

      Design/methodology/approach – In this method, electrostatic field equation is coupled with Navier‐Stokes equation of a drop of water, employing the moving particle semi‐implicit method and FEM. The validity of the method is verified through the measurement.

      Findings – It was found that the difference between calculated and measured results becomes large as the voltage increases.

      Research limitations/implications – In order to improve the accuracy, it is necessary to improve the way to calculate surface tension and the analysis condition.

      Originality/value – This paper confirms the usefulness of the numerical method to elucidate electrostatic atomization.