Ayuda
Ir al contenido

Dialnet


Resumen de Thermal analysis of a high‐energy density pre‐biased choke

Rafal Wrobel, Neville McNeill, Phil H. Mellor

  • Purpose – The main limit of an electromagnetic design lies in its thermal performance. Accurate prediction of the temperature within a new device is therefore very desirable. The purpose of this paper is to present an accurate method of predicting temperature that has been applied for design of a high‐energy density choke.

    Design/methodology/approach – The thermal analysis has been carried out using initially a two‐dimensional (2D) finite element method (FEM) and then a thermal lumped parameter network. The heat flow within the network was informed from the 2D FEM analysis.

    Findings – The presented lumped parameter thermal model of the high‐energy density choke has been experimentally validated and shows good agreement with the test data. The high‐energy density equal to 0.49 J/kg is demonstrated as a result of the improved thermal management and permanent magnet biasing.

    Practical implications – The results show a 1.75 increase of the energy density for the new choke design as compared with more conventional design. The low weight and volume of such components are desirable in many applications including automotive and aerospace.

    Originality/value – The presented method allows for fast temperature predictions that can be used in design and optimisation of high‐energy density inductors.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus