Ayuda
Ir al contenido

Dialnet


Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial

    1. [1] Manipal University

      Manipal University

      India

    2. [2] Professor & Head, Paedodontics & Preventive Dentistry, Manipal College of Dental Sciences, Mangalore, Manipal University, Karnataka State, India
    3. [3] Associate Professor, Microbiology, Kasturba Medical College, Mangalore, Manipal University, Karnataka State, India
    4. [4] Professor, Paedodontics & Preventive Dentistry, Manipal College of Dental Sciences, Mangalore, Manipal University, Karnataka State, India
  • Localización: Journal of Clinical and Experimental Dentistry, ISSN-e 1989-5488, Vol. 9, Nº. 2 (Febrero), 2017, págs. 254-258
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk.

      The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria.

      Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis. Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files.

      Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group.

      Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system.

      Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments.