Ayuda
Ir al contenido

Dialnet


Desempenho de reatores aeróbios de leito fluidizado com circulação interna na remoção de matéria carbonácea tratando diferentes águas residuária

  • Autores: Gleyce Teixeira Correia, Iván Andrés Sánchez Ortiz, Dib Gebara, Milton Dall´Aglio Sobrinho, Tsunao Matsumoto
  • Localización: Interciencia: Revista de ciencia y tecnología de América, ISSN 0378-1844, Vol. 37, Nº. 4, 2012, págs. 266-271
  • Idioma: portugués
  • Texto completo no disponible (Saber más ...)
  • Resumen
    • español

      Se estudió la eficiencia de remoción de materia orgánica (MO) en la forma de DBO (demanda química de oxígeno) y DQO (demanda química de oxígeno) en agua residual doméstica y en efluentes de piscicultura semi-intensiva por medio de reactores aerobios de lecho fluidizado trifásicos con circulación en tubos concéntricos. Se utilizaron tres diferentes relaciones entre las áreas externa e interna con diferentes configuraciones de diámetros internos (100, 125 y 150mm) para un mismo diámetro externo de 250mm; los medios soporte utilizados fueron arena para filtros y carbón activado granular. Los reactores fueron ensayados para tres tiempos de retención hidráulica: 11,5min para el R100, y de 3h para los reactores R125 y R150. Los resultados demostraron que este tipo de reactor presenta un buen desempeño en la remoción de la DBO y DQO para diferentes concentraciones de las aguas residuales. Las eficiencias medias de remoción de la DBO obtenidas fueron: en el reactor R100 de 47%, en el R125 de 57 y 93% de la DBO bruta y filtrada respectivamente, en el R150 de 48 y 89% de la DBO bruta y filtrada.

      Las remociones medias calculadas de la DQO fueron: 75% para el reactor R100, en el R125 de 56 y 86% de la DQO bruta y filtrada, y en el R150 de 54 y 86% de la DQO bruta y filtrada.

      En el caso del agua residual doméstica es necesario disponer de un sistema de remoción de sólidos a la salida del reactor para aumentar la remoción de MO en suspensión del efluente final.

    • English

      The organic matter (OM) removal efficiency in the biochemical oxygen demand (BOD) and chemical oxygen demand (COD) forms for domestic wastewater and semi-intensive fish culture effluents by using three phase aerobic fluidized bed reactors with circulation in concentric tubes was studied. Three different ratios between external and internal areas by different internal diameter configurations (100, 125 and 150mm) to the same external diameter of 250mm were used; sand for filters and granulated activated carbon were used as supporting media. The reactors were tested for three hydraulic retention times: 11.5min to the R100, and 3h for the R125 and R150 reactors. The results demonstrated that this kind of reactors had good performance in the BOD and COD removal for different concentrations of waste waters. BOD mean removal efficiencies obtained were: 47% at the R100 reactor, 57% and 93% of raw and filtered BOD respectively at R125, 48 and 89% of raw and filtered BOD at R150.

      The COD mean calculated removal efficiencies were: 75% at the R100 reactor, 56 and 86% of raw and filtered COD at R125, and 54 and 86% of raw and filtered COD at R150. In the case of domestic wastewater it is necessary to provide a solids removal system at the reactor outflow in order to increase the removal of suspended OM from the final effluent.

    • português

      Foi estudada a eficiência de remoção de matéria orgânica (MO) na forma da DQO (demanda química de oxigênio) e DQO (demanda bioquímica de oxigênio) em esgoto doméstico e efluentes de piscicultura semi-intensiva por meio de reatores aeróbios de leito fluidizado trifásicos com circulação em tubos concêntricos. Foram utilizadas três diferentes relações entre as áreas externa e interna com diferentes configurações de diâmetros internos (100; 125 e 150mm) num mesmo diâmetro externo de 250mm; os meios suporte utilizados foram areia para filtros e carvão ativado granular. Os reatores foram ensaiados em três tempos de retenção hidráulica: 11,5min para o R100, e de 3h para os reatores R125 e R150. Os resultados demonstraram que este tipo de reator apresenta bom desempenho na remoção da DBO e DQO para diferentes concentrações das águas residuárias.

      As eficiências médias de remoção da DBO obtidas foram: no reator R100 de 47%, no R125 de 57 e 93% da DBO bruta e filtrada respectivamente, no R150 de 48 e 89% da DBO bruta e filtrada. As remoções médias calculadas da DQO foram: 75% para o R100, no R125 de 56 e 86% da DQO bruta e filtrada, e no R150 foram 54 e 86% da DQO bruta e filtrada.

      No caso do esgoto doméstico é necessário dispor de um sistema de remoção de sólidos na saída do reator para aumentar a remoção de MO em suspensão do efluente final.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno