Ayuda
Ir al contenido

Dialnet


The Influence of Tightening Sequence and Method on Screw Preload in Implant Superstructures

  • Autores: Maha M. Al Sahan, Riyadh F. Akeel, Nassr Al Maflehi
  • Localización: The International Journal of Prosthodontics, ISSN-e 1942-4426, Vol. 27, Nº. 1, 2014, págs. 76-79
  • Idioma: inglés
  • Enlaces
  • Resumen
    • This study evaluated the effect of six screw-tightening sequences and two tightening methods on the screw preload in implant-supported superstructures. The preload was measured using strain gauges following the screw tightening of a metal framework connected to four implants. The experiment included six sequences ([1] 1-2-3-4, [2] 4-2-3-1, [3] 4-3-1-2, [4] 1-4-2-3, [5] 2-3-4-1, and [6] 3-2-4-1), two methods (onestep, three-step), and five replications. Significant differences were found between tightening sequences and methods. In the three-step method, a higher total preload was found in sequences 2 (312 ± 85 N), 3 (246 ± 54 N), and 4 (310 ± 96 N). In the one-step method, a higher total preload was found in sequences 1 (286 ± 94 N), 5 (764 ± 142 N), and 6 (350 ± 69 N). It is concluded that the highest total screw preload was achieved when anterior implants of the superstructure were first tightened in one step, followed by posterior implants.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno