Ayuda
Ir al contenido

Dialnet


Reliability Assessment of Ballistic Jump Squats and Bench Throws

  • Autores: Joseph A. Alemany, Clay E. Pandorf, Scott J. Montain, John W. Castellani, Alexander P. Tuckow, Bradley C. Nindl
  • Localización: Journal of strength and conditioning research: the research journal of the NSCA, ISSN 1064-8011, Vol. 19, Nº. 1, 2005, págs. 33-38
  • Idioma: inglés
  • Texto completo no disponible (Saber más ...)
  • Resumen
    • The purpose of this investigation was to determine the test-retest reliability and coefficient of variation of 2 novel physical performance tests. Ten healthy men (22.0 ± 3.0 years, 87.0 ± 8.0 kg, 20.0 ± 5.0% body fat) performed 30 continuous and dynamic jump squats (JS) and bench throws (BT) on 4 separate occasions. The movements were performed under loaded conditions utilizing 30% of subject�s predetermined 1 repetition maximum in the back squat and bench press. Mean power (MP; W), peak power (PP; W), mean velocity (MV; m·s-1), peak velocity (PV; m·s-1), and total work (TW; J) were assessed using a ballistic measurement system (Innervations Inc., Muncie, IN).

      Data were analyzed using repeated measures analysis of variance with Duncan�s post hoc test when mean differences were p <= 0.05. Intraclass correlation coefficient (ICC) and within-subject coefficient of variation (CV%) were also calculated. All values are presented as mean ± SE. BT variables were statistically similar across the 4 sessions: MP (350.0 ± 13.9 W), PP (431.4 ± 18.5 W) MV (1.6 ± 0.03 m·s21), PV (2.0 ± 0.03 m·s-1), and TW (199.1 ± 7.2 J). For JS, session 3 PP (1,669.8 ± 111.2 W) was significantly greater vs. sessions 1, 2, and 4 (1,601.2 ± 58.4 W).

      Session 4 MP (1,403.2 ± 88.6 W) and MV (1.9 ± 0.1 m·s-1) for JS were significantly lower during sessions 1, 2, and 3 (MP:

      1,479.4.5 ± 44.8 W, MV: 2.0 ± 0.05 m·s-1). TW (834.7 ± 24.3 J) and PV (2.2 ± 0.04 m·s-1) were staistically similar during all sessions for JS. The CVs ranged from 3.0 to 7.6% for the BT and 3.2 to 5.7% for the JS. ICCs for MP, PP, MV, PV, and TW were 0.92, 0.95, 0.94, 0.91, and 0.95, respectively, during BT. ICCs during JS for MP, PP, MV, PV, and TW were 0.96, 0.98, 0.94, 0.94, and 0.89, respectively. The results of the current study support the use of a 30 continuous and dynamic BT protocol as a reliable upper-body physical performance test, which can be administered with minimal practice. Slightly greater variability for JS was observed, although the test had high reliability.