The government of Spain has developed an energy strategy that includes a campaign of energy audits in water users associations (WUAs) in order to improve energy efficiency in irrigation. A guideline for energy audits has been developed, standardizing the audit process in WUAs. This guideline has been implemented in 22 WUAs in the Castilla-La Mancha, Valencia, and Murcia Regions. In this paper, an analysis of the indicators proposed in the guideline is performed, and the indicators that most represent energy efficiency of WUAs are identified. Also, the suitability of the proposed indicators and classifications under different conditions are discussed. In addition, a cluster analysis is performed on WUAs to classify them according to their energetic aspects. Results show that indicators global energy efficiency (GEE) and active energy consumed per hectare (EacSr) are not adequate for analysing the evolution of energy consumption in a WUA. The most representative energy indicators are those expressing ratios between energy consumption and water volume supplied to the users as the indicators active energy consumed per volume unit (EacVs) and energy cost per volume unit (CENVs). It is conclude that using the current methodology for calculate the supply energy efficiency indicator (SEE), GEE is not an adequate indicator for energy classification of WUAs, and also that the results of the energy analysis must be used to propose measures for energy conservation and energy cost reduction.