Ayuda
Ir al contenido

Dialnet


Relação entre o salto vertical e o teste de 30 metros lançados em velocistas

    1. [1] Universidade Federal do Paraná

      Universidade Federal do Paraná

      Brasil

  • Localización: Lecturas: Educación física y deportes, ISSN-e 1514-3465, Vol. 30, Nº. 323, 2025
  • Idioma: portugués
  • Títulos paralelos:
    • Relación entre el salto vertical y la prueba de 30 metros lanzados en velocistas
    • Relationship between Vertical Jump and the 30-Meter Sprint Test in Sprinters
  • Enlaces
  • Resumen
    • español

      El desempeño en saltos verticales, como el Squat Jump (SJ) y el Counter Movement Jump (CMJ), demuestra una fuerte correlación con pruebas de sprint. Sin embargo, hay una escasez de investigaciones centradas en velocistas de nivel medio en Curitiba, que exploren la relación entre métricas de saltos verticales y desempeño en los 30 metros lanzados. El objetivo de este estudio fue analizar la relación entre las métricas de los saltos verticales (SJ y CMJ) y el desempeño en la prueba de 30 metros lanzados en velocistas. Estudio observacional de carácter analítico y transversal. Dieciséis velocistas, con una edad promedio de 22,8 (±1,77) años y un tiempo promedio de 3,27 segundos (±0,12 segundos) en los 30 metros, realizaron pruebas de SJ y CMJ utilizando una Alfombra de Contacto Jump System CEFISE. Un sistema de fotocélulas midió el tiempo de los 30 metros de sprint. La concordancia y fiabilidad de intentos de salto y sprint se calcularon mediante el Coeficiente de Correlación Intraclase. El análisis de datos se realizó con el software Jamovi versión 2.3.38, con un nivel de significancia del 5%. Se encontraron correlaciones estadísticamente significativas y fuertes entre alturas de saltos SJ y CMJ, así como entre la potencia por kilogramo de masa corporal. Se concluye que las métricas de saltos SJ y CMJ no están relacionadas con el desempeño en la prueba de 30 metros lanzados, y que la fuerza relativa, junto con la potencia, debe ser considerada por los entrenadores en la planificación del entrenamiento.

    • English

      Performance in vertical jumps, such as the Squat Jump (SJ) and Counter Movement Jump (CMJ), shows a strong correlation with sprint tests. However, there is a scarcity of research focusing on medium-level sprinters in Curitiba that explores the relationship between vertical jump metrics and performance in the 30-meter sprint. This study aimed to analyze the relationship between vertical jump metrics (SJ and CMJ) and performance in the 30-meter sprint test among sprinters. This was an observational, analytical, and cross-sectional study. Sixteen sprinters from Curitiba, with a mean age of 22.8 (±1.77) years and an average time of 3.27 seconds (±0.12 seconds) in the 30-meter sprint, performed SJ and CMJ tests using a CEFISE Jump System Contact Mat. A Photocell System measured the 30-meter sprint times. The agreement and reliability of the jump and sprint attempts were calculated using the Intraclass Correlation Coefficient (ICC). Data analysis was conducted using Jamovi software version 2.3.38, with a significance level of 5%. Statistically significant and strong correlations were found between the jump heights in SJ and CMJ, as well as between power per kilogram of body mass. It was concluded that the metrics from the SJ and CMJ jumps are not related to performance in the 30-meter sprint test and that relative strength, along with power, should be considered by coaches in training planning.

    • português

      O desempenho em saltos verticais, como o Squat Jump (SJ) e o Counter Movement Jump (CMJ), demonstra uma forte correlação com testes de sprint. No entanto, há uma escassez de pesquisas focadas em velocistas de nível médio em Curitiba, explorando a relação entre as métricas dos saltos verticais e o desempenho nos 30 metros lançados. O objetivo deste estudo foi analisar a relação entre as métricas dos saltos verticais (SJ e CMJ) e o desempenho no teste de 30 metros lançados em velocistas. Estudo observacional de natureza analítica e transversal. Dezesseis velocistas da cidade de Curitiba, com idade média de 22,8 (±1,77) anos e um tempo médio de 3,27 segundos (±0,12 segundos) nos 30 metros, realizaram testes de SJ e CMJ utilizando um Tapete de Contato Jump System CEFISE. Um Sistema de Fotocélula aferiu o tempo dos 30 metros de sprint. A concordância e a fidedignidade das tentativas de salto e sprint foram calculadas com o Coeficiente de Correlação Intraclasse (CCI). O software Jamovi versão 2.3.38 foi utilizado para a análise dos dados, com um nível de significância de 5%. Foram encontradas correlações estatisticamente significativas e fortes entre as alturas dos saltos SJ e CMJ, bem como entre as potências por quilograma de massa corporal. Conclui-se que as métricas dos saltos SJ e CMJ não apresentam relação com o desempenho no teste de 30 metros lançados, e que a força relativa, assim como a potência, deve ser considerada pelos treinadores no planejamento do treino.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno