Ayuda
Ir al contenido

Dialnet


Step test and physical working capacity in female volleyball players: the paradox of better performance in the older athletes

    1. [1] Universidade Do Porto

      Universidade Do Porto

      Santo Ildefonso, Portugal

    2. [2] University of Zurich

      University of Zurich

      Zürich, Suiza

    3. [3] Universidad Europea de Madrid

      Universidad Europea de Madrid

      Madrid, España

    4. [4] Universidad de Jaén

      Universidad de Jaén

      Jaén, España

  • Localización: Cuadernos de psicología del deporte, ISSN-e 1989-5879, ISSN 1578-8423, Vol. 16, Nº. 2, 2016, págs. 153-160
  • Idioma: español
  • Títulos paralelos:
    • Teste do degrau e capacidade de trabalho em jogadores de voleibol: o paradoxo de um desempenho melhor em jogadores mais velhos
    • Test de Step y capacidad de trabajo en jugadoras de voleibol: la paradoja de un mejor rendimiento en las jugadoras mayores
  • Enlaces
  • Resumen
    • español

      El objetivo del presente estudio fue comparar dos pruebas submáximas de capacidad aeróbica, el YMCA step test y la prueba de capacidad de trabajo físico a 170 ppm (P170) de frecuencia cardíaca (FC), en jugadoras de voleibol femenino. Se analizaron en 152 participantes variables antropométricas, el rendimiento, la frecuencia cardiaca final (Stepend) y la frecuencia cardiaca en el primer minuto de recuperación (Steprec) en la prueba YMCA step test, la P170 fue analizada expresando los resultados en valores absolutos (P170,abs, W) y relativos (P170,rel, W.kg-1). Además, un subgrupo (n=14) fue analizado otra vez después de un año. Los resultados mostraron como el YMCA step test correlacionó altamente (Steprec) y muy altamente (Stepend) con la P170 rel (r = –0.58 and r = –0.76, p < 0.001, respectively), y con la P170,abs (r = –0.54 and r = –0.68, p < 0.001, respectively). No se encontraron correlaciones entre los porcentajes de cambio en los test de capacidad aeróbica después de un año (p>0.05). La edad presentó una correlación baja a moderada con todos los índices de capacidad aeróbica (0.23 ≤ │r│ ≤ 0.45, p<0.05), viendo como las mayores edades tenían una mejor capacidad aeróbica. Basándonos en estos resultados podemos concluir que la prueba YMCA step test (especialmente el parámetro Stepend) y la P170 podrian ser utilizadas indistintamente por entrenadores y preparadores físicos para monitorizar la capacidad aeróbica de jugadoras de voleibol. El paradójico incremento de la capacidad aeróbica con la edad puede ser atribuido a los métodos de evaluación utilizados que están basados en la FC y al descenso de la FC máxima con la edad. Por lo tanto, estos test deberían ser utilizados solo con edades inferiores.

    • English

      The aim of the present study was to compare two popular submaximal tests of aerobic capacity, the YMCA step test and the physical working capacity at heart rate (HR) 170 bpm test (P170), in competitive female volleyball players. The participants (n = 152, age 12.78-41.67 yrs) were examined for anthropometric characteristics and performed the YMCA step test. Heart rate (HR) was recorded at the end of the test (Stepend) and at the end of the first minute of recovery (Steprec). P170 test was expressed in both absolute (P170,abs, W) and relative values (P170,rel, W.kg-1). In addition, a sub-group (n = 14) was tested again one year later. The YMCA step test correlated largely (Steprec) and very largely (Stepend) with P170,rel (r = –0.58 and r = –0.76, p < 0.001, (respectively), and P170,abs (r = –0.54 and r = –0.68, p < 0.001, respectively). No correlation was observed among percentage changes in the tests of aerobic capacity over a year (p>0.05). Age correlated low-to-moderately with all indices of aerobic capacity (0.23 ≤ │r│ ≤ 0.45, p<0.05), i.e. the older the age, the better the aerobic capacity. Based on the findings of the present study, it was concluded that the YMCA step test (especially the Stepend index) and P170 might be used interchangeably by coaches and trainers to monitor aerobic capacity of female volleyball players. The paradoxically increase of aerobic capacity with age should be attributed to the assessment methods which werebased on HR and to the decrease of maximal HR

    • português

      O objetivo deste estudo foi comparar dois testes de capacidade aeróbia submáximas, o teste do degrau YMCA ea capacidade de trabalho fí- sico a 170 ppm (P170) da frequência cardíaca (FC) em jogadores de voleibol das mulheres. Foram analisados 152 variáveis antropométricas envolvidos, o desempenho, a freqüência cardíaca final (Stepend) e freqüência cardíaca no primeiro minuto da recuperação (Steprec) no teste de etapa de teste YMCA, o P170 foi analisado expressando os resultados em valores absolutos (P170 , ABS, W) e relativo (P170, rel, W.kg-1). Além disso, um subgrupo (n = 14) foi analisada outra vez depois de um ano. Os resultados mostraram que o passo de ensaio ACM altamente correlacionados (Steprec) e muito alta (Stepend) com P170 rel (r = -0,58 e r = -0,76, p <0,001, respectivamente), e o P170, ABS (R = -0,54 e r = -0,68, p <0,001, respectivamente). Não há correlação entre a variação percentual no teste de capacidade aeróbica após um ano (p> 0,05). Idade apresentou uma baixa a moderada correlação com todos os índices de capacidade aeróbica (│r│ ≤ 0,23 ≤ 0,45, p <0,05), observando as idades mais velhas tinham melhor capacidade aeróbica. Com base nestes resultados, podemos concluir que o teste de teste YMCA etapa (especialmente parâmetro Stepend) e P170 pode ser usado indiscriminadamente pelos treinadores e preparadores físicos para monitorar a capacidade aeróbia de atletas de voleibol. O aumento paradoxal na capacidade aeróbica com a idade pode ser atribuído aos métodos de avaliação utilizados, que são baseados no FC eo declínio da frequência cardíaca máxima com a idade. Portanto, estes testes devem ser usados apenas com idades mais jovens


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno