INTRODUCTION
Stable and effective anchorage control is the key to good effect of orthodontic treatment. Micro-implants, as the absolute anehorage of orthodontic treatment, are gradually being applied by more clinicians (Khan et al., 2016; Bozkaya et al., 2017; Melsen & Dalstra, 2017). The initial stability of micro-implants has been restricted due to the influence of load intensity and rotation force. The stability of micro-implants anchorage has been a hot research topic in orthodontics (Davoody et al., 2013; Chang & Tseng, 2014; Maino et al., 2016). The biocompatibility and mechanical compatibility of the implant with the bone tissue are reflected in the interface between the implant and the bone tissue and the response of the surrounding bone tissue to the implant.When the microimplants are implanted, the micro-implant-bone interface undergoes a series of inflammatory response?absorption?bone reconstruction and bone plastic construction and other changes, which may eventually lead to the formation of fibrous bone retention and osseointegration (Shah et al., 2016; Buser et al., 2017; Liu et al., 2017). In the experiment, we investigated the changes of implant-bone interface cells and bone histomorphometry around micro-implant by different implantation methods,to explore the effect of implantation on micro-implant osseointegration in order to provide some theoretical basis for clinical practice.
MATERIAL AND METHOD
Experimental animals. Six healthy male beagles aged 18- 20 months and weighing 12-14 kg were provided by the Animal Experimental Center, Shanxi Medical University, China. All dogs had intact dentition and normal occlusion, and they were free from dental caries and periodontal disease.
Experimental materials and equipment. Micro-implant 36 (diameter:1.5 mm, length:7 mm, gingival length: 2.5 mm) and supporting implantation equipment (Dentos, Korea); Leica2035 Tissue Slicers (Germany);NikonEM1200 photographic microscope;S-450 Scanning Electron Microscope (SEM, Hitachi,Japan); BI-2000 medical image acquisition and analysis system (Chengdu Thai League Technology Co, Ltd).
Experimental reagents. Anesthetic: 3 % Pentobarbital sodium, 2 % Lidocaine; Anti-inflammatory drugs: Penicillin, 1 % Iodine, 3 % H2O2; Fixed liquid: Formaldehyde, Paraformaldehyde, Glutaric acid aldehyde, Ketamine, Phosphate buffer; Toluidine blue staining reagent.
Experimental grouping. The root of the second, third and fourth premolar teeth of bilateral maxilla was selected as the implantation site of micro-implant.At the 0th, 4th and 6th week, three micro-implants were implanted on the right and left sides of the maxillary bone in Beagle dogs. One side was implanted by self-tapping and the other was implanted by assisting. At the 8th week of the experiment, the animals were sacrificed and the micro-implant-bone tissue specimens with the healing time of 8w, 4w and 2w were obtained. There were 18 micro-implants in the selftapping implant group and the assistive implant group.
Preparation of hard tissue specimens. Three days after the operation of implanting micro implants with self-tapping implantation and assisting implantation, the planting area was rinsed alternately with 3 % hydrogen peroxide solution and 0.9 % saline solution. The penicillin 800,000 units were intramuscularly injected. Check the micro-implant daily for damage or loss.After 8 weeks, all experimental dogs were overanesthetized and the maxillary bone with implant was removed. Tissue pieces of about 2.0 cm ´ 1.0 cm ´ 1.0 cm were prepared and routinely fixed, dehydrated, soaked and embedded. The long axis was gently cut from the buccal tongue to the tissue block with a slice thickness of 60-80 mm.
Histological observation. The tissue sections of Toluidine Blue staining (TB) was performed on 100 x and 200X microscopy using BI-2000 medical image acquisition and analysis system. The morphology of implant-bone interface was observed under light microscope.
RESULTS
Morphological observation of implant-bone interface cells and bone histomorphology at different healing time using self-tapping implantation method. There were some fibrous tissues surrounding the micro-implants at the 2th week (Fig. 1), the formation of osteoblasts and osteoid was observed at the 4th week (Fig. 2), the wavy and lamellar bone tissues were seen at the 8th week (Fig. 3).
Morphological observation of implant-bone interface cells and bone histomorphology at different healing time using assisting implantation method. More collagen fibers were deposited around the micro-implant at the 2th week (Fig. 4), there were a large number of osteoid-like cells, and the collagen was gradually replaced by the bone tissue at the 4th week (Fig. 5), the osteoblasts were active and the osteoblasts were linear arrange and form a laminate bone at the 8th week. (Fig. 6).
DISCUSSION
Micro - implant anchorage has been widely used in orthodontic clinical practice, and the research on the stability of micro-implant has been a hotspot in this field because of its practical effect? convenient and flexible implantation comfortable wearing and no dependence on the characteristics of patient cooperation (Favero et al., 2010; Wahabuddin et al., 2015; Turkkahraman & Sarioglu, 2016). The biocompatibility and mechanical compatibility of the implant with the bone tissue are reflected in the interface between the implant and the bone tissue and the response of the surrounding bone tissue to the implant (Seifi & Matini, 2016). Branemark Osseointegration concept was proposed in the 1970 s, and a good combination of state phalanx of tissue implant material. In this study, 60-80 mm superhard tissue sections were successfully fabricated by Leica1600 sawing machine. The sections were stained with toluidine blue to clearly observe the morphology of the cells around the implant and the surrounding bone histomorpholog.
The main purpose of this study is to investigate the effect of micro-implants implanted with different surgical techniques on osseointegration. Self-tapping implantation is the microimplant directly into the cortical bone, micro-implants in the implantation process may cause extrusion of the surrounding bone tissue, the pressure may promote osteoblast response, stimulate bone formation. But at the same time, excessive pressure may also cause local bone ischemia and necrosis, while self-tapping bone debris is not easy to discharge, resistance is too large in the local bone easily lead to stress concentration, implant stability is difficult to guarantee (Gupta et al., 2012; Jasoria et al., 2013). Assisted implantation of the channel intact, smooth, screwed into the screw basically no resistance, fixed after the formation of axial tension, so you can make microimplant to obtain greater retention. If the hole diameter is too large, it will easily lead to micro-implant loose after implantation. And assistive implant surgery greater trauma, too much heat can also affect the stability (Wu et al., 2008; Sivakumar & Sivakumar, 2014).
The combination of micro-implant with the maxilla first heals the fiber and then gradually produces a small amount of bone healing (Basha et al., 2010; Antoszewska- Smith et al., 2017). Whether the micro-screw anchorage implant and jaw healing form is the healing of fibrous tissue or bone tissue, as the supporting force can not exceed a certain range. At the initial stage of implant implantation, implants and bone tissue interface between the micromobility of more than 50 mm ~ 150 mm will be formed on the surface of the implant fibers wrapped.In this study, we observed that regardless of the implanting method, fiber healing and bone healing were observed in each time period. The difference between groups was only in the degree of bone healing different. Complete bone contact was not formed at 8 weeks, and more fibroids formed at 2 weeks to meet the clinical needs of orthodontics.
Whether implanted self-tapping or assisted implantation, micro-implant-bone interface reconstruction can occur. If the clinical need for early loading force, microimplant try to choose self-tapping implantation. By appropriately prolonging the healing time, the initial stability of the micro-implant under assistive implantation can be improved.