Intra-session stability of short-term heart rate variability measurement: gender and total spectral power influence

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/39578
Información del item - Informació de l'item - Item information
Título: Intra-session stability of short-term heart rate variability measurement: gender and total spectral power influence
Autor/es: Cipryan, Lukas | Litschmannova, Martina
Palabras clave: Heart rate variability | Reliability | Autonomic nervous system | Test-retest | Orthoclinostatic
Área/s de conocimiento: Educación Física y Deportiva
Fecha de publicación: 2014
Editor: Universidad de Alicante. Área de Educación Física y Deporte
Cita bibliográfica: Journal of Human Sport and Exercise. 2014, 9(1): 68-80. doi:10.4100/jhse.2014.91.08
Resumen: Heart rate variability (HRV) has been increasingly analysed under numerous research settings. HRV measurement reliability is, however, still an unresolved issue. The main purpose is to carry out an intra-session stability evaluation of HRV parameters from short-term recordings by means of orthoclinostatic stimulation in a study group which is stratified by gender or Total Power (PT) magnitude. The goal is to make as homogeneous a study group as possible and investigate whether the reproducibility level could be influenced by these factors. The study group consisted of 103 participants (age 22.3 ± 1.2). Standard HRV indexes were computed: PT (total spectral power), PHF (high frequency spectral power), PLF (low frequency spectral power) and LF/HF. Absolute reliability is assessed by the standard error of measurement and 95% limits of agreement; the relative reliability is assessed by the intraclass correlation coefficient. The markedly different standard error of measurement (SEM) between the Male and Female groups was not observed for any HRV parameters. The intraclass correlation coefficient (ICC) values ranged from 0.67 to 0.95 for males and from 0.69 to 0.97 for females. According to the SEM and ICC, there is no difference between the groups of High PT and Low PT. There are not any significant differences in absolute or relative reliability between the more homogeneous study groups and we have therefore concluded that HRV measurement reliability is not influenced by gender or HRV magnitude.
URI: http://hdl.handle.net/10045/39578
ISSN: 1988-5202
DOI: 10.4100/jhse.2014.91.08
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: Licencia Creative Commons Reconocimiento-NoComercial-SinObraDerivada 4.0
Revisión científica: si
Versión del editor: http://dx.doi.org/10.4100/jhse.2014.91.08
Aparece en las colecciones:Journal of Human Sport and Exercise - 2014, Vol. 9, No. 1

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnailjhse_Vol_9_N_I_68-80.pdf273 kBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons